    Major Types of EV Charging Charger and their requests for Energy Meter and DC IMD

    Type 1: Small 1-phase AC EV Charger
    - Noted: Request below are request of EV charging station
    to the energy meter used by it.
    - Rated Voltage: Request rated voltage in the range of 220~
    264Vac L-N (1-phase)
    - Rated Current: Request Max current at least 60A AC
    - Communication: Request RS485 communication for control function
    - Metering: Request Multi-rate/tariff metering as a optional  function

    • Charger2bs4

    Type 2: Small 3-phase AC EV Charger
    - Noted: Request below are request of EV charging station
    to the energy meter used by it.
    - Rated Voltage: Request rated voltage in the range of 380~
    456Vac L-L & 220~264Vac L-N (3-phase)
    - Rated Current: Request Max current input at least 80A AC
     (direct connect type) or Max 5A AC current input (via CTs)
    - Communication: Request RS485 communication for control function
    - Metering: Request Multi-rate/tariff metering as a optional 
    function

    • Charger3de2

    Type 3: Medium&Large DC EV Charger
    - Rated Voltage: Request rated voltage in the range of 200~
    1000Vdc
    - Rated Current: Request Max current input normally not 
    more that 500A DC
    - Communication: Request RS485 communication for control function
    - Metering: Request Multi-rate/tariff metering as a optional 
    function
    - Insulation: Request insulation monitoring for EV Charger 
    between the DC+ and ground or DC- pole and ground.

    • Charger4ejc

    Energy Meter Model Selection (For Small 1-phase AC EV Charger Energy Monitoring)

    Type & Name

    Picture

    Description

    ADL200

    1-phase DIN-rail Energy Meter

    Charger5.jpg

    - Rated Voltage: 220~264Vac L-N (45~65Hz)

    - Rated Current: 10(80)A AC

    - Accuracy: Class 1.0 for active energy monitoring

    - Communicaiton: RS485 Interface, MODBUS-RTU Protocol

    - Extra Function: Multi-rate/tariff metering & Pulse Output

    - Certificate&Standard: IEC; CE; CE-MID;EAC

    ADL10-E

    1-phase DIN-rail Energy Meter

    Charger6.jpg

    - Rated Voltage: 220~264Vac L-N (45~65Hz)

    - Rated Current: 10(60)A AC

    - Accuracy: Class 1.0 for active energy monitoring

    - Communicaiton: RS485 Interface, MODBUS-RTU Protocol

    - Certificate&Standard: CE; EAC

    ADL400

    3-phase DIN-rail Energy Meter

    Charger7.jpg

    - Rated Voltage: 3x380~456Vac L-L & 220~264Vac L-N (45~65Hz)

    - Rated Current: 3x10(80)A AC (direct connect) or 3x1(6)A AC (via CTs)

    - Accuracy: Class 0.5S for active energy monitoring

    - Harmonic: Total and 2~31st harmonic monitoring

    - Communicaiton: RS485 Interface, MODBUS-RTU Protocol

    - Extra Function: Multi-rate/tariff metering & Pulse Output

    - Certificate&Standard: IEC; CE; CE-MID;EAC

    ADL3000-E

    3-phase DIN-rail Energy Meter

    Charger8.jpg

    - Rated Voltage: 3x380~456Vac L-L & 220~264Vac L-N (45~65Hz)

    - Rated Current: 3x10(80)A AC (direct connect) or 3x1(6)A AC (via CTs)

    - Accuracy: Class 0.5S for active energy monitoring

    - Communicaiton: RS485 Interface, MODBUS-RTU Protocol

    - Certificate&Standard: UL; CE; IEC; EAC


    AIM-D100-CA

    DC Insulation Monitoring Device

    Charger9.jpg

    - Application: for DC EV charger Insulation Monitoring

    - Insulation Resistance Monitoring Range: 1kΩ~10MΩ

    - Insulation Alarming Range: 10kΩ~10MΩ

    - Insulation Monitoring Mode: Triggered by RS485 Comms.

    - Voltage Monitoring: 0~1000Vdc [0.5 Accuracy]

    - Communicaiton: RS485 Interface, MODBUS-RTU Protocol

    - Extra Current Monitoring: 1-channel DC current metering

    via shunt; 5% accuracy [module name AIM-D100-CAI]

    - Auxiliary Power Supply: 9~36Vdc

    - Certificate&Standard: CE

    DJSF1352-RN

    DC Din-rail Energy Meter

    Charger10.jpg

    - Voltage Input Range: 0~1000Vdc

    - Current Input Range: 0~5Vdc, 4~20mA DC (via Hall

    Sensor) 0~75mV (via Shunt) and etc.

    - Accuracy: Class 1.0 for active energy monitoring

    - Communicaiton: RS485 Interface, MODBUS-RTU Protocol

    - Extra Function: Multi-rate/tariff metering & Optional Dual Circuits Monitoring

    - Certificate&Standard: CE, UL

    PZ72L-DE

    DC Panel mounted Energy Meter

    Charger11.jpg

    - Voltage Input Range: 0~1000Vdc

    - Current Input Range: 0~5Vdc, 4~20mA DC (via Hall

    Sensor) 0~75mV (via Shunt) and etc.

    - Accuracy: Class 1.0 for active energy monitoring

    - Communicaiton: RS485 Interface, MODBUS-RTU Protocol

    - Extra Function: Multi-rate/tariff metering

    - Certificate&Standard: CE