    Acrel AGF-MXXT DC1500V Multi-channel Monitoring Device

    Products

    Products Categories
    Featured Products

    Acrel AGF-MXXT DC1500V Multi-channel Monitoring Device

    Model:AGF-M4T AGF-M8T AGF-M16T AGF-M24T

    ● Measurement: DC Current of up to 24 Circuits

    ● Communication: RS485 (MODBUS-RTU)

    ● DI Function: 3-channel Digital Input

    ● Display: LCD Display

    ● Installation: 35mm DIN Rail (Main Body); Perforation (Cable)

    ● Power Supply: 1000V DC or 1500V DC

    ● Standard&Certificate: CE;LVD;EMC

      Scenario Application Project

      asdzxcxz2b78

      Characteristics
      ◆ Primary current is connected in through perforation. Easy installation, high safety. 
      ◆ With Hall sensor, the max isolation measuring current 20A
      ◆ Voltage measurement range for Bus bar is up to DC1.5kV
      ◆ LED display, fit for checking and testing operation in wide-temperature or outside environment. 
      ◆ With the function of inner temperature measurement for real-time measurement of the inner temperature of combiner box
      ◆ With RS485 Modbus RTU
      ◆ More options of power supply
      ◆ Compatible with din rail installation and baseboard fixation installation, small dimension savingmorebox space. 

      FUNCTIONS

      ◆ Photovoltaic cell open circuit alarm to cooperate with group string voltage and judge Comprehensively

      ◆ With 3-channel switching state monitoring to collect output idle contact information of DCbreaker 、lightning protector. protector etc 

      ◆ Option RS485 port, Modbus-RTU protocol; programmable slave address, baud rate, dataformat 

      ◆ English LCD display,convenient to set parameters and check the data

      Multi-circuits Measurement up to 24 DC Circuits ● Input Channel: up to 24 Circuits ● LED Indicator for Re-flux, Disconnection, Over-current ● Rated Current: 20A ● Accuracy: 0.5 Class ● Voltage Measuring Range: up to 1500V (Busbar)

      asdzxcxz3zji
      3-Channel DI Switch Status Monitoring ● DI Status of Lightning Protector and DC CB ● Octocoupler or dry Contact

      asdzxcxz4u92
      Keypads HMI for Programming ● Communication(address, baud rate and etc.) ● Over-temp Alarm Threshold asdzxcxz5q01

      TECHNICAL PARAMETERS

      Item

      AGF-M4T

      AGF-M8T

      AGF-M12T

      AGF-M16T

      AGF-M20T

      AGF-M24T

      Input channels

      4

      8

      12

      16

      20

      24

      Rated current

      DC 0~20A

      Response time

      1s

      Accuracy

      0.5 class

      Temperature

      coefficient

      400ppm

      RS485

      communication

      RS485/ModBus-RTU protocol,4800/9600/19200/38400bps

      Additional function

      Switch input

      3-way input(optocoupler or dry contact mode)

      General technical parameters

      Temperature/

      Humidity

      Working temperature: -35~+65℃, humidity95%,no condensation, no corrosion gas place *Display module work temperature:-20~+70℃

      Temperature measurement function

      To measure the inner temperature of box (-20℃~100℃)

      Altitude

      ≤3000m

      Insulation

      resistance

      ≥100MΩ

      Industrial frequency

      withstand

      voltage

      power/communication/switching input/cell voltage input--AC 2kV/1min (When the auxiliary power supply is DC1500V, the withstand voltage between the power supply, photocell input and other circuit is AC 2.7kV) Current input/power、cell voltage 、communication、switching state—AC3.5kV/1min

      EMC

      GB_T 17626.2-2006; Electrostatic discharge immunity test 3rd grade, air discharge 8kV, contact discharge 6kV.
      GB_T 17626.4-2008; Electrical fast transient immunity test grade 4, common mode 4kV, difference mode 2kV
      GB_T 17626.5-2008; Surge(shock) immunity test grade 4, common mode 4kV, difference mode 2kV
      GB_T 17626.8-2006; Power frequency magnetic field immunity test grade 4

      WIRING

      asdzxcxz19wu

      Note: The arrow shows current direction. Wrong connection will lead to abnormal operation of the device.

      • asdzxcxz6qm2
      • asdzxcxz75dw

      DIMENSION & INSTALLATION

      -----Power supply module size

      asdzxcxztl2

      Note: Imaginary line is the fixing size of the bottom plate

      As power supply module is heavy, bottom plate is needed in installation to avoid its coming off during transportation.

      ----8-channel confluence acquisition module installation dimension

      asdzxcxz9k4m

      ---4-channel confluence acquisition module installation dimension

      asdzxcxz10abq

      NETWORK

      asdzxcxz11cxe
      pdf (4)ns0
      AGF-T Perforation type PV confluence acquisition device
      pdf (4)ns0
      CE Certificate-1 of AGF-MxxT Series
      pdf (4)ns0
      CE Certificate-2 of AGF-MxxT Series
      pdf (4)ns0
      EMC Certificate of AGF-MxxT Series
      pdf (4)ns0
      LVD Certificate of AGF-MxxT Series

      By INvengo TO KNOW MORE ABOUT INVENGO RFID, PLEASE CONTACT US!

      Our experts will solve them in no time.