• Phone
  • E-mail
  • Whatsapp
  • Whatsapp
    cf541b0e-1eed-4f16-ab78-5cb5ce535649s3e
  • Leave Your Message

    ASCB1-MS-WIFI-4G Wireless Smart Circuit Breaker Gateway

    Products

    Products Categories
    Featured Products

    ASCB1-MS-WIFI-4G Wireless Smart Circuit Breaker Gateway

    ● Model:ASCB1-MS ASCB1-MS-CE ASCB1-MS-WIFI ASCB1-MS-4G

    ●Communication:support RS485,Internet,WIFI,4G communication

    ●Display:LCD

    ●Support connect 16-channel Smart Circuit Breaker

    ●Switch;1DI/1DO

      picture

      standard

      optional

      asdzxc1l8y

      ASCB1-MS

      ● Can connect to up to 16 intelligent micro circuit breakers
      ● See, the real-time data of voltage, current, power, power, temperature and leakage of each intelligent micro circuit breaker
      ● You can view the fault, alarm and separation status of each intelligent micro circuit breaker
      ● It can set and control the parameters for each intelligent micro circuit breaker
      ● Din rail type installation, LCD LCD display
      ● Support event logging; support RS485 communication

      None

       

      picture

      standard

      optional

      asdzxc2wjh

      ASCB1-MS-CE

      ● Can connect to up to 16 intelligent micro circuit breakers
      ● See, the real-time data of voltage, current, power, power, temperature and leakage of each intelligent micro circuit breaker
      ● You can view the fault, alarm and separation status of each intelligent micro circuit breaker
      ● It can set and control the parameters for each intelligent micro circuit breaker
      ● Din rail type installation, LCD LCD display
      ● Support event logging; support RS485 communication
      ● Support for Ethernet communication.

      None

       

      picture

      standard

      optional

      asdzxc335v

      ASCB1-MS-WIFI

      ● Can connect to up to 16 intelligent micro circuit breakers
      ● See, the real-time data of voltage, current, power, power, temperature and leakage of each intelligent micro circuit breaker
      ● You can view the fault, alarm and separation status of each intelligent micro circuit breaker
      ● It can set and control the parameters for each intelligent micro circuit breaker
      ● Din rail type installation, LCD LCD display
      ● Support event logging; support RS485 communication
      ● Support for WIFI communication.

      None

       

      picture

      standard

      optional

      asdzxc4t86

      ASCB1-MS-4G

      ● Can connect to up to 16 intelligent micro circuit breakers ● See, the real-time data of voltage, current, power, power, temperature and leakage of each intelligent micro circuit breaker ● You can view the fault, alarm and separation status of each intelligent micro circuit breaker ● It can set and control the parameters for each intelligent micro circuit breaker ● Din rail type installation, LCD LCD display ● Support event logging; support RS485 communication ● Support for 4G-LTE communication.

      None

      Appearance

      • 2f2a0fc557ae5bba0bd5752d55aec82da0r
      • 2dfc833a7783519a0321a0e8da7b7645okk
      • 33530d6b00d18977240c574e3fa24daaq43
      ASCB1-M
      Length
      Width
      Height
      Parameter(mm)
      109
      36
      75.5

      Parameters

      Product Model
      ASCB1-M-4G
      ASCB1-M-CE
      Power Supply
      AC 220V
      Consumption
      ≤30W
      Communication
      4G
      Ethernet
      Display
      LCD dot-matrix
      Incident Record
      Up to 20 alarm, fault and action records each
      Protocol
      Modbus、MQTT and so on
      Elevation Requirements
      2000m
      Ambient Temperature
      -10℃-55℃,24h the average temperature is not higher than 40℃
      Environmental Requirements
      No explosion hazard, no conductive dust, no sufficient corrosion of metal and damaged insulation, no significant vibration
      Relative Humidity
      At + 40℃, the relative humidity of the air is 50% and can have high relative humidity at lower temperatures
      Storage Temperature
      -20℃-70℃
      Levels of Protection
      IP20
      Way to Installation
       Standard 35mm guide rail installation

      Function

      ASCB1 Smart Gateway Function
      ASCB1-M-CE
      · Can connect to up to 16 intelligent micro circuit breakers · See, the real-time data of voltage, current, power, power, temperature and leakage of each intelligent micro circuit breaker · You can view the fault, alarm and separation status of each intelligent micro circuit breaker · It can set and control the parameters for each intelligent micro circuit breaker · Din rail type installation, LCD LCD display · Support event logging; support RS485 communication · Support for Ethernet communication.
      ASCB1-M-4G
      · It can connect to up to 16 smart micro circuit breakers · Can see the real-time data of voltage, current, power, power, temperature and leakage of each intelligent micro circuit breaker · Can view the fault, alarm and separation status of each intelligent micro circuit breaker · It can set and control the parameters for each intelligent micro circuit breaker · Din rail type installation; LCD LCD display · Support event logging; support RS485 communication · Support for 4G network communication

      Wiring

      3bf348fad95f87db243d1f12b0cf6394hvc
      • baa6f32798e291cb6d135daf1d51e6b58beStep1: Connect the RS485 port on the gateway to the BUS port of the circuit breaker by using the communication cable provided by the gateway
      • b69caabba25b31673ba1884f0705b92155cStep2: Insert the barbed side of the connecting wire of the circuit breaker into the external terminal of the previous circuit breaker toward the outside of the terminal, and the colors need to be matched one by one.
      9e059dc9c43565767259cb904965ece6pwv

      Typical Connection

      e1789892503af7c3eff3d2725a781583p2w

      FAQ

      Q: Can the circuit breaker data be collected through RS485 communication?

      A: The circuit breaker has its own RS485 communication interface, and it does not need to be equipped with an ASCB1-M gateway to access the customer system, but the customer needs to provide the circuit breaker with DC12V 12A auxiliary power supply

      Q: How many circuit breakers can a gateway carry?

      A: 16PCS

      Q: How Gateways and Circuit Breakers are Networked?

      A: The gateway and the circuit breaker are connected by a 4pin cable, a set of DC12V auxiliary power supply, and a set of RS485 communication lines.
      The connection between the circuit breaker and the circuit breaker is the same.
      One-key addressing operation through the gateway

      Q: Does the circuit breaker need to be equipped with additional accessories?

      A: 1. Internally integrate various sensor modules, including: current sensor, leakage transformer, temperature sensor, etc.;
      2. The circuit breaker integrates the release function, which can realize remote opening and closing operations;
      3. Configure the circuit breaker network cable

      pdf (4)ns0
      ASCB1-63
      pdf (4)ns0
      ASCB1LE-63
      pdf (4)ns0
      ASCB1第三方检测报告
      pdf (4)ns0
      ASCB1强制性认证产品符合性自我声明
      pdf (4)ns0
      S591 ManualofASCB1SeriesofIntelligentMicro-CircuitBreakersV1.00

      Leave Your Message