• Phone
  • E-mail
  • Whatsapp
  • Whatsapp
    cf541b0e-1eed-4f16-ab78-5cb5ce535649s3e
  • Leave Your Message

    AMC72L-E4 Multi-Function Three phase energy meter

    Products

    Products Categories
    Featured Products

    AMC72L-E4 Multi-Function Three phase energy meter

    ● Four quadrant energy metering

    ● System time display

    ● RS485

    ● Modbus-RTU protocol and the statute DLT645

      4a6f23c858d6cffe78423ab5a0e427dbnmm

      GENERAL

      AMC series meters adopt AC sampling technology, which can measure the current ,voltage,power, power factor and electric energy parameters in the power grid separately. It can set the magnification through the panel membrane switch. The meters have RS485 communication interface, adopt Modbus protocol; also can convert the power signal into a standard DC analog signal.

      Parameters

      Accuracy
      Active energy: Class 0.5

      Frequency
      Range: 45-65Hz

      Auxiliary power supply
      AC/DC 85~265V

      Consumption
      Voltage: Power consumption <0.5VA;
      Current: Power consumption< 0.5VA;
      Auxiliary power supply:power consumption≤10VA

      433be80125fb14306764c237f9bd6ebe (1)j8c

      Installation
      Panel mounted

      Dimension(L*W*H)
      Panel size (L×W): 75*75mm
      Cutout (L×W): 67*67mm
      Depth (H): 94.3mm

      Contact Capacity
      DC 30V/3A AC 220V/3A

      Pulse output
      1600-160000imp/kWh

      debd654228ea1d3921f9b5ddf0674668mu5

      Technical Datasheet

      Technical Parameters Value
      Input Connection

      Single phase-2 wire,3 phase-3 wire,3 phase 4-wire

      Frequency 45-65Hz
      Voltage

      Rating:

      Single-phase:AC 100V、400V

      Three-phase:AC 3x57.7V/100V(100V)、3x220V/380V(400V)

      3x380V/660V(660V)(96 size only)

      Note:72 profile not suitable for high voltage application

       
      Overload:1.2 fold rating(continuous):2 fold rating for 1 second
      Power consumption:<0.5VA
      Current Rating:AC 1A、5A
      Overload:1.2 fold rating(continuous):10 fold rating for 1 second
      Power consumption:<0.5VA
      Output Electric energy Output mode:open-collector photo-coupler pulse
      Pulse constant:10000imp/kWh(settable),see wiring diagram for details
      Communication RS485 port,Modbus-RTU protocol,DLT645 protocol(versions 09 and 97),baud rate 1200-38400
      Function Switching input Dry contact input,built-in power supply
      Switching output Output mode:Relay normally open contact output
      Contact capacity:AC 250V/3A、DC 30V/3A
      Analog output 1-5V,4-20mA
      Accuracy Class

      Frequency:0.05Hz,Current、Voltage;0.2 class,Reactive

      Power:1.0 class,Reactice Electric energy:1.0 class active

      Power:0.5 class,active electric energy:0.5 class,2-31th harmonic

      measurement:±1%

      Power Supply AC/DC 85-265V Power consumption≤10VA
      Security

      Power frequency

      withstand voltage

      Between Power supply//Switching Output//Current input//voltage input and

      Transmitting//Communication//Pulse Output//switching input AC 2kV 1min;

      Between Power supply、switching output、Current input、voltage input AC 2kV 1min;

      Between Transmitting、Communication、Pulse Output、switching input AC 1kV 1 min;

      Insulation resistance Input、Output end to machine enclosure>100MΩ
      Environment Temperature work:-25℃~+65℃ storage:-40℃~+80℃
      Humidity ≤93%RH Non-condensing
      Altitude ≤2500m

      Dimension

      Dimensionepk

      Wiring

      Wiringos3

      Network

      Networkqyx

      Installation

      Installationedr

      FAQ

      Q: No display on power?
      A: Check whether the supply voltage is within the operating voltage range.

      Q: Incorrect reading of voltage,current, electricty, etc?
      A: Checking that the voltage/current ratio setting are correct;
      Checking whether the wiring mode setting is consistent with the actual situation;
      Checking whether the voltage transformer and current transformer are in good condition.

      Q: Abnormal communication
      A: Check whether the adress,baud rate,check bits in the communication;
      Setting are consistent with the host computer;
      Check whether the RS485 converter is normal;
      Check the connection is corrent if the resistor above 120 ohm is connected in parallel at the communication end.

       

      PACKAGE

      MINIMUM PACKAGE

      Packagevry Package2z9y Package35xu Packagepmd

      MINIMUM PACKAGE

      Package Dimension(1 PC)

      230*145*120mm

      Pakage Weight(1 PC)

      0.52Kg

      WHOLE BOX PACKAGE

      Package dimensions(36 PCS)

      615*480*395mm

      Pakage Weight(36 PCS)

      13kG

      PRODUCT HS CODE

      9028301400

      ATTENTION !

      The above packing and weight data are only refer to model AMC72L-E4/KC.

      For other models or optional functions, please contact the salesman for details, thank you for your cooperation!

      pdf (4)ns0
      【Certificate】Acrel ADL200 Single Phase Smart Energy Meter CE-MID
      pdf (4)ns0
      【Certificate】Acrel ADL200 Single Phase Smart Energy Meter CE-MID
      pdf (4)ns0
      【Certificate】Acrel ADL200 Single Phase Smart Energy Meter CE-MID

      Leave Your Message