• Phone
  • E-mail
  • Whatsapp
  • Whatsapp
    afe4e218-0c7c-4ab6-9678-d9f155e62bc1xn1
  • Leave Your Message

    APM520 series 3-phase Multifunction Power Meter

    Panel Three Phase Energy Meter

    Products Categories
    Featured Products

    APM520 series 3-phase Multifunction Power Meter

    ● Full Power Measurement

    ● Power Quality Analysis

    ● Leakage Current Measurement (Optional)

    ● Support Modbus-RTU/TCP Protocol

    ● Accuracy: 0.5s

      picture standard optional optional group
      APM520tuxAPM520

      Full electric parameter measurement (I, U, kW, kvar, kWh, kvarh, Hz, cos);

      four-quadrant electric energy, split-phase electric energy, apparent electric energy;

      real-time demand and maximum demand;

      electric parameter extreme value and last month Monthly extremevalue;

      voltage and current unbalance;

      voltage and current phase angle;

      total harmonic and 2nd-63rd subharmonic;

      voltage crest factor, telephone waveform factor, current K coefficient, vector diagram, voltage and current waveform;

      last 128 pcs of DIDO Records;

      the latest 128 pcs of alarm records ;

      default switch communication 4DI2D02EP1C;

      1.K(2DI2DO) 1+2+3+4+5
      4+5+6+11+12
      4+5+7+11+12
      4+5+8+11+12
      4+5+9+11+12
      4+5+10+11+12
      2.2M(2 channel analog)
      3.2C(The second RS485)
      4.F(Multi tariff)
      5.S(Class 0.2S+fault recording)
      6.WF(WiFi)
      7.LR(Lora)
      8.CE(Ethernet)
      9.4G(4G communication)
      10.NB(NB communication)
      11.T(Temperature measurement)
      12.L(Residual current measurement)

      GENERAL

      APM5 series network power meter (hereinafter referred to as the meter) is designed according to IEC international standards, with full power measurement, power statistics, power quality analysis (including harmonics, interharmonics, flicker), fault recording function (including voltage temporary rise and fall interrupt, inrush current and other records), event recording function and network communication and other functions. It is mainly used for comprehensive monitoring of power supply quality in the power grid.

      FUNCTIONS

      Accuracy
      Voltage、current and power: Class 0.2
      Active power: Class 0.5; Reactive power: Class 1

      Pulse Output 
      Output mode: photocoupler pulse with open collector;
      Pulse constant: 10000imp/kWh (default)

      Consumption
      Voltage、current: Power consumption: <0.5VA;
      Auxiliary power supply: Power consumption ≤15VA

      Starting Current: 0.1%

      Parameteryy2

      Installation: Panel mounted

      Frequency: Range: 45-65Hz

      Relay: 3A/AC250V, 3A/DC30V

      Dimension (L*W*H)
      Panel size (L×W): 96*96mm
      Cut-out size (L×W): 88*88mm

      Auxiliary Power Supply
      AC/DC 85V~265V or AC/DC 115~415V

      Parameter2eum

      Display

      Displayjbz

      Front Panel

      ① Type of Parameters

      ② Load Value

      ③ Total Power

      ④ DO Status Indicator

      ⑤ Menu

      ⑥ Key Down

      ⑦ Data Display

      ⑧ Navbar

      ⑨ DI Status Indicator

      ⑩ Enter Button

      ⑪ Key up

      Front Panelif1

      Wiring

      Wiring380

      Network

      Networkqwu

      Installation

      Installationiat

      Application

      Applicationk6f

      FAQ

      Q: What’s the storage capacity, storage format and data storage interval of SD card?
      A: The meter is equiped with standard 4G SD card while saving the data of electrical parameter, energy, event, SOE, alarm. Also, the setting of storage interval could be changed. (1 min interval for electrical parameter and 1 hour interval for energy) .

      Q: How should I select the expanded modules of APM5xx?
      A: Our users can select 3 of the optional modules at will even repeatly except for communication module. Also, the order of module installation could be random.

      Q: The features of APM5xx?
      A: Except for wave record and flicker record function, 0.2S measuring accuracy can also be a option. Also, users can measure the data through browser by using Ethernet auto WEB.

      Q: As for the auxiliary power supply of APM5xx?
      A: AC/DC 85~265V or 115~415V is both optional. Also, 380V  line voltage can also serve as power supply.

      PACKAGE

      MINIMUM PACKAGE

      Packageep8

      Package2ixd

      Package3cyw

      Package437s

      MINIMUM PAKAGE

      Package dimensions(1 PC)

      170*150*130mm

      Net Weight(1 PC)

      0.78KG

      WHOLE BOX PAKAGE

      Package dimensions(36 PCS)

      540*530*480mm

      Package Weight(36 PCS)

      15.2kG

      PRODUCT HS CODE

      9028301400

      ATTENTION !

      The above packing and weight data are only refer to model APM520.

      For other models or optional functions, please contact the salesman for details, thank you for your cooperation!

      pdf (4)ns0
      [Certificate]APM520 CE-EMC certificate
      pdf (4)ns0
      [Certificate]APM520 CE-LVD certificate
      pdf (4)ns0
      [Manual]Acrel APM520 power meter installation guide
      pdf (4)ns0
      [Report]78251EC20064101 APM520 CE-EMC report

      Leave Your Message